Vertical Multistage Centrifugal Pump

CDL and CDLF are versatile products capable of conveying various media ranging from tapwater to industrial liguids, suitable for different temperature, flow rate, and pressure rangesCDL is designed for non-corrosive liquids, while CDLF is suitable for mildly corrosive liquids.
  • Product Description
  • Application scenarios

    CDL and CDLF are versatile products capable of conveying various media ranging from tapwater to industrial liguids, suitable for different temperature, flow rate, and pressure rangesCDL is designed for non-corrosive liquids, while CDLF is suitable for mildly corrosive liquids.

    Water supply:

    -Water plant filtration and conveyance
    -Zoned water distribution in water plants
    -Main pipeline boosting
    -High-rise building pressure boosting

    Industrial Boosting

    -Process water systems
    -Cleaning systems
    -High-pressure washing systems
    -Firefighting systems

    Industrial Liquid Conveyance:
    - Cooling and air conditioning systems
    -Boiler feedwater and condensation systems
    -Machine tool integration
    -Acid and alkali handling

    Water Treatment:
    - Ultrafiltration systems
    -Reverse osmosis systems
    -Distillation systems
    -Separators
    -Swimming pools

    Irrigation:
    - Farmland irrigation
    -Sprinkler irrigation
    -Drip irrigation

    Operating Conditions

    Thin, clean, non-flammable, non-explosive liquids free of solid particles or fibersLiquid temperature:
    Standard type: -15℃ to +70℃
    -Hot water type: -15℃ to +105℃
    Ambient temperature: Maximum +40℃
    Altitude:Maximum 1000m

    Pump introduction

    The CDL and CDLF are non-self-priming vertical multistage centrifugal pumps equipped withstandard motors. The motor shaft is directly connected to the pump shaft via a couplingthrough the pump head. The pressure cylinder and flow passage components are securelyfastened between the pump head and the inlet/outlet sections by tie rods. The pump inletand outlet are positioned on the same horizontal line at the pump base.Additionally, the pump can be optionally equipped with an intelligent protector for effectivesafeguarding against dry running, phase loss, overload, and other operational anomalies.

    Motor

    The motor is a fully enclosed, fan-cooled, two-pole standard motor.Protection Class: IP54,1P55
    Insulation Class: F
    Standard Voltage:50 Hz, 380 V
    Motors with other voltage specifications are available upon request.

    Model Designation

    Example:CDL8-20
    CDL: Light-Duty Vertical Multistage Centrifugal Pump
    8: Rated Flow
    20: Number ofStages
    Example:CDLF8-20
    CDLF:The wetted parts are made of stainless steel 304 or 316L.8:Rated Flow
    20:Number of StagesExample: CDL32-30-2
    CDL: Light-Duty Vertical Multistage Centrifugal Pump
    32: Rated Flow
    30:Numberofstagesx10
    2:Numberofsmall impellers
    Example:CDLF32-30-2
    CDLF: The wetted parts are made of stainless steel 304 or 316L.32: Rated Flow
    30:Numberofstagesx10
    2:Number ofsmall impellers

    Performance Curves

    The following explanations apply to the curves shown hereafter:
    1. All curves are based on measurements with the motor at a constant speed of 2900 rpm or2950 rpm.
    2. Curve tolerances comply with ls0 9906, Annex A.
    3. Tests were conducted using air-free water at 20° Cwith a kinematic viscosity of 1 mm2/s.
    4. The operation of the pump should refer to the performance range indicated by the boldsection of the curve to prevent overheating due to too low flow or motor overload due toexcessive flow.

    Performance Range

    Instructions CDL2 CDL4 CDL8 CDL12 CDL16 CDL20 CDL32 CDL42 CDL64 CDL85
    Rated Flow (m³/h) 2 4 8 12 16 20 32 42 64 85
    Rated Flow (l/s) 0.56 1.1 2.2 3.3 4.4 5.6 8.9 12.5 17.8 25
    Flow Range (m³/h) 1-3.5 1.5-7 5-12 7-16 8-22 10-28 16-40 25-55 30-80 50-110
    Flow Range (l/s) 0.28-0.97 0.42-1.9 1.4-3.3 1.9-4.4 2.2-6.1 2.8-7.8 4.4-11.1 6.9-15.3 8.3-22.2 13.8-30.5
    Maximum Pressure (bar) 23 21 21 22 22 23 29 30 22 17
    Motor Power (KW) 0.37-3 0.37-4 0.75-7.5 1.5-11 2.2-15 1.1-18.5 1.5-30 3-45 4-45 5.5-45
    Temperature Range (°C)           -15°+120        
    Maximum Efficiency (%) 46 57 62 63 66 69 73 75 76 77
    DN Flange DN25 DN32 DN40 DN50 DN50 DN50 DN65 DN80 DN100 DN100
    Type                    
    CDL
    CDLF

    Cross-Sectional Diagram

    NO. Name Material AISI/ASTM
    1 Motor Molectron  
    3 Support Cast iron/ductile iron  
    4 Mechanical seal Molectron  
    5 Outlet guide vane Stainless steel AISI304
    6 Guide vane Stainless steel AISI304
    7 Support guide vane Stainless steel AISI304
    8 Nature gas diverter Stainless steel AISI304
    11 Pump bearing Tungsten carbide/alloy  
    12 Impeller Stainless steel AISI304
    13 Shaft Stainless steel AISI304、316L
    14 Impeller casing Stainless steel AISI304
    15 Pressure cylinder Stainless steel AISI304
      CDLF    
    16 Coupling Steel/metal powder  
    3 Seal sert Stainless steel AISI304
    9 Inlet and outlet section Stainless steel AISI304
    10 Base Cast iron  
      CDL    
    9 Inlet and outlet section Cast iron  
    16 Coupling Steel/metal powder  

    Cross-sectional diagram and material notes

    correspond to model: CDL/CDLF2, 4

    NO. Name Material AISI/ASTM
    1 Motor Molectron  
    2 Support Cast iron/ductile iron  
    4 Mechanical seal Molectron  
    5 Outlet guide vane Stainless steel AISI304
    6 Guide vane Stainless steel AISI304
    7 Support guide vane Stainless steel AISI304
    8 Nature gas diverter Stainless steel AISI304
    11 Pump bearing Tungsten carbide/alloy  
    12 Impeller Stainless steel AISI304
    13 Shaft Stainless steel AISI304、316L
    14 Impeller casing Stainless steel AISI304
    15 Pressure cylinder Stainless steel AISI304
      CDLF    
    16 Coupling Steel/metal powder  
    3 Pump head lining Stainless steel AISI304
    9 Inlet and outlet section Stainless steel AISI304
    10 Base Cast iron  
      CDL    
    9 Inlet and outlet section Cast iron  
    16 Coupling Steel/metal powder  

    Cross-sectional diagrams and material notes

    correspond to the following models: CDL/CDLF8,CDL/CDLF12,CDL/CDLF16, CDL/CDLF20.

    NO. Name Material AISI/ASTM
    1 Motor Molectron  
    2 Support Cast iron/ductile iron  
    4 Mechanical seal Molectron  
    5 Outlet guide vane Stainless steel AISI304
    6 Guide vane Stainless steel AISI304
    7 Support guide vane Stainless steel AISI304
    8 Coupling Steel/metal powder  
    9 Impeller Stainless steel AISI304
    10 Pump casing Stainless steel AISI304
    11 Pump Shaft Stainless steel AISI304AISI316LAISI431
    12 Pump bearing Tungsten carbide/alloy  
    13 Inlet guide vane Stainless steel AISI304
      CDLF    
    3 Seal seat Stainless steel AISI304
    14 Inlet and outlet section Stainless steel AISI304
    15 Base Cast iron ASTM25B
      CDL    
    3 Seal seat Cast iron/Ductile iron ASTM25BASTM70-50-05
    14 Inlet and outlet section Cast iron/Ductile iron ASTM25BASTM70-50-05

    Cross-Sectional Diagram and Material Notes for Models: CDL/CDLF32,42,64,85,120,150

    Pump Installation

    - The pump should be installed in a well-ventilated and frost-protected location. Ensure aminimum cearance of 150 mm between the pump, motor, and any obstructions to allowsufficient airflow around the motor's cooling fan.
    - Inlet piping should be as short as possible to minimize friction losses at the suction side.
    - Before installing the pump, verify that a check valve is installed in the piping system toprevent backflow of liquid. lf the pump is used for boiler feedwater supply, a check valvemust be installed on the delivery line between the pump and the boiler.
    - The pump should be mounted on a concrete or similarly stable foundation of appropriateheight, or securely fixed on a rigid floor-mounted or wall-mounted bracket. Care must betaken to avoid concentrating the weight of the piping onto the pump, which could causedamage to the pump structure.

    *During pump installation, it is strictly prohibited to mount the motor in an inverted position on a horizontal surface.

    The "->" mark on the inlet and outlet sections of the pump indicates the direction of liquid flowthrough the pump. Before starting the pump, ensure that liquid can pass freely.Prior to pump installation, the inlet pipeline must be flushed clean. lf it cannot be guaranteedthat the pipeline is free of particles, a strainer must be installed 0.5-1 m before the pump suctioninlet (especially recommended for pumps with a flow rate below 8 m/h) to ensure normal pumpoperation.
    During installation of the inlet pipeline, care must be taken to avoid air pockets (see Figure 3).If there is a possibility that the shut-off valve on the outlet side may close (or flow may drop tozero), a bypass line must be installed on the outlet pipeline to ensure sufficient lubricating andcooling water passes through the pump.

    Electrical Connection

    - Electrical wiring must be carried out by a qualified electrician with appropriate certification.

    - Verify that the motor is compatible with the power supply being used. The motor leads must beconnected to the power source in accordance with the wiring diagram attached to the terminabox and the specifications on the motor nameplate.

    - The motor must be connected to a quick and effective motor starter to ensure protectionagainst phase loss, voltage instability, and overload. The pump motor must be reliably grounded

    * Before removing the motor terminal box cover or disassembling the pump, ensure that the power supply has been disconnected.

    Start-up, Operation and Maintenance

    * Before starting up, carefully read the warning sign on the pump pressure cylinder.

    1. The pump must be fully filled with water (or the liquid to be conveyed) before starting.Priming the pump in a flooded suction system:

    Close the pump outlet valve. Open the vent plug on the pump head. Gradually open theinlet valve until a steady flow of liquid discharges from the vent plug, then tighten the ventplug. Fully open the check valve on the suction pipeline.

    Priming the pump in an open system where the liquid level is below the pump:

    * Note: A check valve must be installed on the suction pipeline.

    Close the pump outlet valve, open the vent plug on the pump head, and fill the pump withliquid through the vent plug hole until both the pump and the suction pipeline arecompletelwfledwith liquid.Then retightenvent Dlug

    * Do not start the pump until it is completely filled with liquid and all air hasbeen thoroughly vented!

    * Note the orientation of the vent hole on the vent plug. Take care to ensure that anyoverflowing liquid does not cause injury to personnel or damage to the pump and othercomponents. In hot water applications, exercise extreme caution to avoid the risk ofscalding!

    2.Check Rotation Direction

    Turn on the power and observe the rotation direction (check the fan). The correct rotationdirection is indicated by the arrow on the pump head, i.e., viewed from the motor drive endthe pump should rotate counterclockwise.

    3. Pre-Start Checks

    - Ensure the anchor bolts are tightened.
    - Verify the pump is fully filled with liquid.
    -Confirm the grid voltage is correct.
    Check that the rotation direction is correct.
    - Ensure all pipelines are tightly connected and can supply water normally.
    - Confirm the valve on the inlet pipeline is fully open; the outlet valve should be slowlyopened after the pump has started.
    - lf a pressure gauge is installed, check the operating pressure.- Verify all controls required for normal operation. lf the pump is controlled by a pressureswitch, check and adjust the start and stop pressures. Use the pressure switch to confirmthat the motor's full-load current does not exceed the maximum allowable current.

    4. Pump Start Frequency

    The pump should not be started too frequently.Recommended limits:
    -For motors ≤4 kW: no more than 100 starts per hour.

    -For motors >4 kW: no more than 20 starts per hour.If frequent starts are observed, adjust the control equipment to reduce the start-stopfrequency. lt may also be necessary to review the installation conditions.

    5.Pump Operation

    Operate the pump within the performance range indicated by the bold section of the curveto prevent overheating due to insufficient flow or motor overload caused by excessive flow.

    6.Maintenance

    When installed according to this manual, the pump will operate efficiently with minimalmaintenance:
    - The mechanical seal is self-adjusting, and the contact surfaces of its stationary and rotatingfaces are lubricated and cooled by the pumped liquid.(For pumps with motors larger than 7.5 kW, the mechanical seal can be replaced withoutdismantling the motor.)
    - The pump's sliding bearings are lubricated by the pumped liquid.

    7. Freezing Prevention

    The pump may be used in systems where water is protected against freezing. lf installed in alocation prone to frost, an appropriate antifreeze solution must be added to the pumpedliquid to prevent ice damage.
    If antifreeze is not used, the pump must be shut down when frost risk exists, and both thepump and system must be completely drained.

    8. Regular lnspections

    Perform periodic checks of:
    -Pump operation and working pressure,
    -Possible motor overheating;
    -Trip time of motor overload protection;
    -Proper functioning of all controls;
    -Possible leaks;
    -Removal, cleaning,and replacement of all strainers;
    Frequency of starts and stops.
    If any abnormality is found, refer to the section “Common Faults and Troubleshooting” forcorrective actions.

    9. Long-Term Shutdownlf the pump is to be out of service for an extended period, it shouldbe thoroughly cleaned and stored properly.

    10. StorageDuring storage, protect the pump against corrosion and physical damage.

    Assembly and Disassembly

    1. CDL/CDLF2, 4 Pumps
    - Slide the retaining ring onto the shaft, followed by the spacer, impeller, impeller spacerdiffuser, support diffuser, and so on, until the last impeller is installed. Then, attach theimpeller cover plate, washer, and tighten the nut. Pay attention to the position of thesupport diffuser: for pumps with fewer stages, the last component is the support diffuser; forpumps with more stages, additional support diffusers should be added at evenly spacedintervals, along with support spacers and bearings as required.
    - Install the flow guide into the inlet/outlet section and base, then mount the assembledrotor component onto the flow guide
    - Fit an O-ring onto the inlet/outlet section, slide the pressure cylinder over it, and install theoutlet diffuser.

    - Place the pump head (already equipped with its O-ring, liner, and wire spring) over thepressure cylinder. Tighten the four tie-rod nuts on the base evenly-do not tighten one nutcompletely at a time; instead, tighten them symmetrically and gradually in sequence.
    - install the mechanical seal and secure it. Mount the motor and coupling, then thread thescrews on the coupling (but do not fully tighten yet). Push the coupling (including the pumpshaft) fully toward the base, then pull it back approximately 1 mm in the opposite directionbefore tightening the screws. Ensure the gap between the two coupling halves is uniformacross the mating surfaces.
    - Tighten the set screws on the mechanical seal. Rotate the coupling by hand to verify thatthe shaft turns smoothly without any binding or looseness.Disassembly of the pump follows the reverse of the above steps.

    2.CDL/CDLF Models 8,10,12,16,20 Pumps

    - Slide the retaining ring onto the shaft, followed by the impeller, impeller spacer, diffusersupport diffuser, bearing, support spacer, and so on, until the last impeller is installed. Thenattach the impeller cover plate, washer, and tighten the nut.

    - Assemble the inlet/outlet section onto the base, and install the O-ring, inlet partition plateand flow guide. Then mount the previously assembled rotor component onto the flow guide.Install the outlet diffuser and tie-rod, tighten the bolts, and fit the pressure cylinder.- Place the pump head (already equipped with its 0-ring, liner, and rubber adjustment pinover the pressure cylinder. Tighten the four nuts on the tie rods symmetrically and graduallyin sequence.
    - lnstall the mechanical seal and secure it. Mount the motor and coupling, then thread thescrews on the coupling (but do not fully tighten yet). Push the coupling (including the pumpshaft) fully toward the base, then pull it back approximately 1 mm in the opposite directionbefore tightening the screws. Ensure the gap between the two coupling halves is uniformacross the mating surfaces.
    - Tighten the set screws on the mechanical seal. Rotate the coupling by hand to verify thatthe shaft turns smoothly without any binding or looseness.Disassembly of the pump follows the reverse of the above steps.

    3.CDL/CDLF Models 32,42,64,85 Pumps

    - Install the inlet/outlet section onto the base, slide flanges onto both sides, and mount theflow guide.
    - Mount the first impeller onto the shaft, tighten the nut, and fit the impeller into the wearring seat of the flow guide. lnstall the diffuser, impeller, support diffuser, and proceed insequence up to the outlet diffuser. Secure all diffusers with tie rods.
    - Shaft assembly: Install the lower shaft sleeve, gland plate, and washer; tighten the screws.Mount the lower sliding bearing into the inlet/outlet section, fit the washer, and tighten thescrews. Then reinstall the shaft assembly into the inlet/outlet section, fit the O-ring, applylubricant, and slide the pressure cylinder into place.
    - Mount the tie rods onto the base. Fit the O-ring, adjustment pin, vent plug, and air releaseplug onto the pump head. Then position the pump head over the tie rods, install the washers.and tighten the nuts.
    - Install the mechanical seal onto the pump head, mount the seal gland plate, and tightenthe screws. Then tighten the screws on the mechanical seal. Lift the shaft upward and instalthe adjustment shim.
    -Mount the bracket and motor onto the pump head.Finally, install the coupling and tighten the screws. Then remove the adjustment shim.Rotate the coupling by hand to verify that the pump shaft turns smoothly without binding orooseness.
    Disassembly of the pump follows the reverse of the above steps.

    4.CDL/CDLF Models 120,150 Pumps

    - Install the inlet/outlet section onto the base, slide flanges onto both sides, and mount theflow guide.
    - Assemble the support washer, shaft sleeve, inlet impeller spacer, gland plate, and washeronto the pump shaft, then tighten the nut.
    - Install the impeller sleeve and impeller onto the shaft, and tighten the impeller nut,ensuring that dimension A in Figure 4is 14.3mm for models CDL(F)20, 150.
    -Place the assembled shaft into the flow guide until it seats properly. install the supportdiffuser, impeller sleeve, impeller, and tighten the impeller nut. Then proceed to install thediffuser, impeller, and subsequent components in sequence until the last diffuser ismounted.
    - install the outlet body and secure all diffusers with tie rods. fit the O-ring onto the watersection, apply lubricant, and slide the pressure cylinder over it.
    - Mount the tie rods onto the base. Install the O-ring, adjustment pin, plug, and othercomponents onto the pump head. Then place the pump head over the tie rods, fit thewashers, and tighten the nuts.
    Mount the bracket and motor onto the pump head. Then install the coupling, tighten thescrews,and remove the adjustment shim.Rotate the coupling by hand to verify that the pump shaft turns smoothly without binding orooseness.
    Disassembly of the pump follows the reverse of the above steps.

    Common Faults and Troubleshooting

    * Before removing the motor terminal box cover or disassembling the pump, ensure that the power supply has been disconnected.

    Fault Phenomenon Cause Analysis Troubleshooting Method Remarks
    When the starter is engaged, the motor fails to start. a) Power supply failureb) Fuse blownc) Motor overloadd) Poor contact in the starter or faulty coile) Control circuit malfunctionf) Motor fault a) Check the power supplyb) Replace the fusec) Check the systemd) Replace the startere) Check the control circuitf) Repair or replace the motor  
    The overload protection device trips of the starter upon immediately upon power connection. a) Fuse blownb) Overload protection device contact faultc) Loose cable connection or power supply issued) Motor winding faulte) Mechanical jamming of the pump a) Replace the fuseb) Check the starterc) Check cable connections and power supplyd) Replace the motore) Overhaul the pump Items d and e must not be disassembled or repaired by users without authorization.
    Overload protection device trips occasionally. a) Overload setting too lowb) Periodic power supply failurec) Low voltage during peak power usage a) Reset the overload settingb) Check and repair the power supplyc) Install a voltage stabilizer  
    The overload protection device does not trip, but the pump fails to operate. a) Poor contact in the starter or faulty coilb) Control circuit malfunction a) Replace the starterb) Check the control circuit  
    Uneven pump discharge (pump a) Inlet pipe diameter too smallb) Insufficient water supply at the pump a) Increase the diameter of the inlet pipe  
    Fault Phenomenon Cause Analysis Troubleshooting Method Remarks
    output fluctuates). c) Liquid level too lowd) Inlet pressure is too low relative to water temperature, pipeline losses, and flow ratee) Inlet pipe partially clogged with debris c) Raise the liquid leveld) Improve the system to increase inlet pressuree) Inspect and clean the inlet pipe  
    The pump is running but no water is discharged. a) Inlet pipe clogged with debrisb) Foot valve or check valve stuck in closed positionc) Inlet pipe leakaged) Air trapped in the inlet pipe or pump a) Inspect and clean the inlet pipeb) Check the foot valve and check valvec) Repair the inlet piped) Refill the pump with liquid and vent air  
    When the power is disconnected, the pump runs in the reverse direction. a) Inlet pipe leakageb) Foot valve or check valve malfunctionc) Foot valve stuck in open or partially open positiond) Air pocket in the inlet pipe a) Repair the inlet pipeb) Repair or replace the foot valve and check valvec) Repair or adjust the foot valved) Repair the inlet pipe and vent air pockets  
    The pump has abnormal vibration and noise. a) Inlet pipe leakageb) Inlet pipe diameter too small or partially clogged with debrisc) Air trapped in the inlet pipe or pumpd) System head is too low relative to pump heade) Mechanical rubbing inside the pump a) Repair the inlet pipeb) Increase the pipe diameter or repair the inlet pipec) Refill the pump with liquid and vent aird) Improve the system or reselect the pump modele) Overhaul the pump Item e must not be disassembled or repaired by users without authorization.

    Important Notes

    1. The content of this operation manual is subject to change without prior notice.

    2. Provided that the user selects the appropriate model and operates the pump correctly, thepump is covered by a one-year warranty. Normal wear and tear of consumable parts are notincluded in this warranty.

    3. lf the user disassembles the pump without authorization during the warranty period, anyresulting qualityissues will be the sole responsibility of the user.

    Technical Data Sheet, Performance Curves, and Dimensional Drawings

    Performance Curves

    50HZ, 2900rpm

    Installation Dimension Drawings

    Data Sheet

    Model 1 1.2 1.6 2.0 2.4 2.8 3.2 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
    Flow (m³/h) B1  B2 H  D1 D2
    CDL(F)2-20 18 17 16 15 13 12 10 Head(m) 0.37 15 279 225 504 148 117 20
    CDL(F)2-30 27 26 24 22 20 18 15 0.37 22 297 225 522 148 117 20
    CDL(F)2-40 36 35 33 30 26 24 20 0.75 30 315 265 580 170 142 22
    CDL(F)2-50 45 43 40 37 33 30 25 0.75 37 333 265 598 170 142 23
    CDL(F)2-60 54 52 50 45 40 36 30 0.75 45 351 265 616 170 142 26
    CDL(F)2-70 63 61 57 52 47 41 35 0.75 52 369 265 634 170 142 26
    CDL(F)2-80 71 70 65 59 54 48 40 1.1 60 387 265 652 170 142 28
    CDL(F)2-90 81 78 73 67 71 54 45 1.1 67 405 265 670 170 142 28
    CDL(F)2-100 90 87 81 74 67 59 50 1.1 75 423 265 688 170 142 29
    CDL(F)2-110 98 95 89 82 73 64 55 1.1 82 441 265 706 170 142 29
    CDL(F)2-120 108 104 98 90 81 71 60 1.5 90 469 305 774 190 155 35
    CDL(F)2-130 116 114 106 98 89 78 65 1.5 98 487 305 774 190 155 35
    CDL(F)2-140 126 122 115 105 95 84 70 1.5 105 505 305 810 190 155 36
    CDL(F)2-150 134 130 123 112 100 90 75 1.5 112 523 305 828 190 155 36
    CDL(F)2-160 144 139 132 120 107 96 80 2.2 120 541 305 846 190 155 37
    CDL(F)2-170 153 148 140 128 114 102 85 2.2 128 559 305 864 190 155 37
    CDL(F)2-180 161 157 148 136 121 108 90 2.2 136 577 305 882 190 155 41
    CDL(F)2-190 170 166 156 143 128 114 90 2.2 143 595 305 900 190 155 41
    CDL(F)2-200 179 175 164 150 135 120 105 2.2 150 613 305 918 190 155 42
    CDL(F)2-210 188 184 172 157 142 126 105 2.2 157 631 305 936 190 155 42
    CDL(F)2-220 197 192 180 165 148 132 110 2.2 165 649 305 954 190 155 43
    CDL(F)2-230 206 201 189 173 156 139 115 3 173 675 335 1010 197 165 51
    CDL(F)2-240 215 210 197 181 163 146 120 3 181 693 335 1028 197 165 51
    CDL(F)2-250 224 219 206 189 171 152 125 3 189 711 335 1046 197 165 52
    CDL(F)2-260 232 228 214 198 179 158 130 3 198 729 335 1064 197 165 52

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Model 2 3 4 5 6 7 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
    Flow (m³/h) B1  B2 H  D1 D2
    CDL(F)4-20 18 17 15 13 10 8 Head
    (m)
    0.37 15 297 225 522 148 117 21
    CDL(F)4-30 27 26 24 20 18 13 0.55 24 324 265 589 170 142 22
    CDL(F)4-40 36 35 32 27 24 19 0.75 32 351 265 616 170 142 25
    CDL(F)4-50 45 44 40 34 31 23 1.1 40 378 265 643 170 142 27
    CDL(F)4-60 54 53 48 41 37 28 1.1 48 405 265 670 170 142 27
    CDL(F)4-70 63 62 55 48 43 33 1.5 55 442 305 747 190 155 33
    CDL(F)4-80 72 71 64 55 50 38 1.5 64 469 305 774 190 155 33
    CDL(F)4-90 81 80 72 62 56 43 2.2 72 496 305 801 190 155 37
    CDL(F)4-100 90 89 81 69 62 48 2.2 81 523 305 828 190 155 37
    CDL(F)4-110 99 98 88 76 69 53 2.2 88 550 305 855 190 155 38
    CDL(F)4-120 108 107 95 83 75 58 2.2 95 577 305 882 190 155 38
    CDL(F)4-130 117 106 104 90 82 63 3 104 614 335 949 197 165 46
    CDL(F)4-140 126 125 112 97 89 68 3 112 641 335 985 197 165 46
    CDL(F)4-150 135 134 121 104 95 73 3 121 668 335 1003 197 165 47
    CDL(F)4-160 144 143 129 111 101 78 3 129 695 335 1030 197 165 48
    CDL(F)4-170 153 152 137 118 108 83 4 137 722 365 1087 230 188 56
    CDL(F)4-180 162 161 145 125 115 88 4 145 749 365 1114 230 188 57
    CDL(F)4-190 171 170 153 132 122 93 4 153 776 365 1141 230 188 57
    CDL(F)4-200 180 179 162 139 128 98 4 162 803 365 1168 230 188 58
    CDL(F)4-210 189 188 170 146 133 103 4 170 830 365 1195 230 188 58
    CDL(F)4-220 198 197 178 154 138 108 4 178 857 365 1222 230 188 59

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Model 5 6 7 8 9 10 11 12 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
     Flow (8m³/h)  B1  B2  H  D1 D2
    CDL(F)8-20 20 19.5 19 18 17 16 14 13 Head
    (m)
    0.75 18 350 265 615 170 142 32
    CDL(F)8-30 30 29.5 28.5 28 25 24 21 19 1.1 28 380 265 645 170 142 34
    CDL(F)8-40 41 39.5 38 36 34 32 28 26 1.5 36 415 305 720 190 155 40
    CDL(F)8-50 52 50 48 45 42 40 36 32 2.2 45 445 305 750 190 155 44
    CDL(F)8-60 62 60 57 54 51 48 43 39 2.2 54 475 305 780 190 155 45
    CDL(F)8-70 72 70 67 64 60 57 51 45 3 64 520 335 873 197 165 52
    CDL(F)8-80 83 80 77 73 69 65 58 52 3 73 573 335 903 197 165 53
    CDL(F)8-90 93 90 87 83 78 73 66 58 4 83 603 365 948 230 188 63
    CDL(F)8-100 104 100 97 92 87 81 73 65 4 92 633 365 978 230 188 64
    CDL(F)8-110 114 110 107 101 96 87 80 71 4 101 663 365 1008 230 188 65
    CDL(F)8-120 124 120 116 111 104 92 87 78 4 111 693 365 1038 230 188 66
    CDL(F)8-130 134 131 126 119 113 98 95 85 5.5 119 725 425 1150 260 208 80
    CDL(F)8-140 145 141 136 130 122 113 102 92 5.5 130 755 425 1180 260 208 81
    CDL(F)8-150 155 151 146 138 131 122 110 99 5.5 138 785 425 1210 260 208 82
    CDL(F)8-160 166 161 156 148 139 130 118 106 5.5 148 815 425 1240 260 208 83
    CDL(F)8-170 177 171 166 156 148 138 126 113 7.5 156 845 425 1270 260 208 92
    CDL(F)8-180 187 182 175 167 157 146 134 120 7.5 167 875 425 1300 260 208 93
    CDL(F)8-190 197 192 185 175 166 155 142 127 7.5 175 905 425 1330 260 208 94
    CDL(F)8-200 108 202 195 186 175 163 150 135 7.5 186 935 425 1360 260 208 95
    CDL(F)8-210 218 212 205 195 184 171 158 143 7.5 195 965 425 1390 260 208 96
    CDL(F)8-220 228 222 215 205 193 179 166 151 7.5 205 995 425 1420 260 208 97

    Performance Curves

    Installation Dimension Drawings

    Model 7 8 9 10 11 12 13 14 15 16 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
    Flow (12m³/h) B1 B2 H D1 D2
    CDL(F)12-20 23 23 22 22 21 20 18 17 15 14 Head
    (m)
    1.5 20 384 295 679 190 155 39
    CDL(F)12-30 35 35 34 33 31 30 28 26 23 21 2.2 30 416 295 711 190 155 43
    CDL(F)12-40 47 46 45 44 42 40 37 34 31 28 3 40 461 330 791 197 165 51
    CDL(F)12-50 49 58 56 55 52 50 46 43 39 35 3 50 493 330 823 197 165 53
    CDL(F)12-60 71 70 68 66 63 60 56 52 47 42 4 60 525 345 870 230 188 61
    CDL(F)12-70 83 82 79 77 73 70 65 61 55 49 5.5 70 579 390 969 260 208 72
    CDL(F)12-80 95 94 91 88 84 80 75 70 63 56 5.5 80 611 390 1001 260 208 74
    CDL(F)12-90 108 106 103 101 95 91 85 79 71 64 5.5 91 643 390 1033 260 208 76
    CDL(F)12-100 120 118 114 111 106 101 94 88 80 72 7.5 101 675 390 1065 260 208 83
    CDL(F)12-110 132 130 126 122 117 111 104 97 88 79 7.5 111 707 390 1097 260 208 84
    CDL(F)12-120 143 141 137 133 127 121 113 106 96 86 7.5 121 739 390 1129 260 208 87
    CDL(F)12-130 155 153 149 144 138 131 124 118 104 93 7.5 131 858 500 1358 330 255 155
    CDL(F)12-140 168 165 160 155 148 141 132 124 112 100 11 141 890 500 1390 330 255 157
    CDL(F)12-150 180 177 172 166 159 151 142 133 120 107 11 151 922 500 1422 330 255 159
    CDL(F)12-160 192 189 183 178 170 162 152 142 128 115 11 162 954 500 1454 330 255 161
    CDL(F)12-170 204 201 195 190 181 171 162 151 137 122 11 171 986 500 1486 330 255 163
    CDL(F)12-180 217 213 207 202 192 183 171 160 145 130 11 183 1018 500 1518 330 255 165

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Data Sheet

     

    Model 8 10 12 14 16 18 20 22 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
    Flow (16m³/h) B1 B2 H D1 D2
    CDL(F)16-20 27 26 25 24 23 21 19 16 Head (m) 2.2 23 400 305 705 190 155 42
    CDL(F)16-30 41 40 38 37 35 32 29 25 3 35 460 335 795 197 165 50
    CDL(F)16-40 54 53 52 49 47 43 38 34 4 47 510 365 885 230 188 59
    CDL(F)16-50 68 67 65 62 59 54 48 43 5.5 59 580 390 970 260 208 76
    CDL(F)16-60 82 80 78 74 70 64 58 52 5.5 70 625 390 1015 260 208 77
    CDL(F)16-70 96 95 91 87 82 76 68 61 7.5 82 670 390 1060 260 208 84
    CDL(F)16-80 110 108 104 99 94 86 77 70 7.5 94 715 390 1105 260 208 86
    CDL(F)16-90 124 122 118 112 106 98 87 78 11 106 783 500 1283 330 255 155
    CDL(F)16-100 138 136 131 125 118 109 97 87 11 118 828 500 1328 330 255 157
    CDL(F)16-110 152 149 144 138 129 120 106 96 11 129 873 500 1373 330 255 159
    CDL(F)16-120 166 162 157 150 141 130 116 105 11 141 918 500 1418 330 255 161
    CDL(F)16-130 180 176 171 163 153 141 126 114 15 153 963 500 1463 330 255 172
    CDL(F)16-140 194 190 184 175 165 152 136 122 15 165 1008 500 1508 330 255 174
    CDL(F)16-150 208 203 197 188 177 163 146 131 15 177 1053 500 1553 330 255 176
    CDL(F)16-160 222 217 210 200 189 174 156 140 15 189 1098 500 1598 330 255 178
    CDL(F)16-170 236 230 223 212 202 185 165 149 15 202 1143 500 1643 330 255 180

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Data Sheet

    Model 10 12 14 16 18 20 22 24 26 28 Flow (m³/h) Power (KW) Head (m) Size(mm)         Weight (KG)
    Flow (20m³/h) B1 B2 H D1 D2
    CDL(F)20-10 13 13 12 12 11 10 9 8 7 6 Head (m) 1.1 10 360 245 605 170 142 33
    CDL(F)20-20 27 26 26 25 24 23 22 20 18 15 2.2 23 400 295 695 190 155 42
    CDL(F)20-30 40 39 39 38 37 35 33 30 27 24 4 35 460 345 805 230 188 58
    CDL(F)20-40 54 53 52 51 49 47 44 41 37 33 5.5 47 535 390 925 260 208 74
    CDL(F)20-50 67 66 64 62 60 58 55 50 45 40 5.5 58 580 390 970 260 208 76
    CDL(F)20-60 81 79 77 75 73 70 66 61 55 49 7.5 70 625 390 1015 260 208 82
    CDL(F)20-70 95 93 91 89 86 82 77 71 65 58 7.5 82 670 390 1060 260 208 84
    CDL(F)20-80 109 107 105 102 99 94 89 82 75 67 11 94 738 500 1238 330 255 153
    CDL(F)20-90 122 120 118 115 112 106 100 93 85 76 11 106 738 500 1238 330 255 155
    CDL(F)20-100 136 134 131 128 124 118 111 103 95 85 11 118 828 500 1328 330 255 157
    CDL(F)20-110 150 148 145 141 137 130 122 114 105 94 15 130 873 500 1373 330 255 168
    CDL(F)20-120 164 162 158 154 149 142 133 124 114 102 15 142 918 500 1418 330 255 170
    CDL(F)20-130 178 175 171 167 162 154 145 135 124 111 15 154 963 500 1463 330 255 172
    CDL(F)20-140 192 189 185 180 174 166 156 145 133 119 15 166 1008 500 1508 330 255 174
    CDL(F)20-150 206 203 198 193 187 178 168 156 143 128 18.5 178 1053 550 1603 330 255 191
    CDL(F)20-160 220 216 212 206 200 190 179 167 153 137 18.5 190 1098 550 1648 330 255 193
    CDL(F)20-170 234 230 225 219 212 202 190 177 162 145 18.5 202 1143 550 1693 330 255 195

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Model 16 20 24 28 32 36 40 Flow (m³/h) Power (KW) Head (m) Size(mm)
    B1
    Size(mm) Weight (KG)
    Flow (32m³/h) B2 H D1 D2
    CDL(F)32-10-1 14 13 12 11 9 7 4 Head (m) 1.5 9 510 305 795 190 155 64
    CDL(F)32-10 18 17 15 14 13 11 8 2.2 13 510 305 795 190 155 68
    CDL(F)32-20-2 29 28 26 23 20 16 11 3 20 580 330 920 197 165 77
    CDL(F)32-20 36 34 32 29 27 23 18 4 27 580 365 930 230 180 85
    CDL(F)32-30-2 47 44 41 38 33 28 21 5.5 33 650 425 1035 260 208 100
    CDL(F)32-30 54 51 48 44 40 35 27 5.5 40 650 425 1035 260 208 100
    CDL(F)32-40-2 65 62 58 53 46 40 30 7.5 46 720 425 1105 260 208 109
    CDL(F)32-40 72 69 65 59 53 47 37 7.5 53 720 425 1105 260 208 109
    CDL(F)32-50-2 83 79 74 68 60 52 41 11 60 900 500 1460 260 208 125
    CDL(F)32-50 90 86 81 74 67 59 47 11 67 900 500 1460 260 208 125
    CDL(F)32-60-2 101 97 90 83 74 65 51 11 74 970 500 1460 330 255 185
    CDL(F)32-60 108 104 97 90 81 72 57 11 81 970 500 1460 330 255 185
    CDL(F)32-70-2 119 114 107 98 88 78 60 15 88 1040 500 1530 330 255 199
    CDL(F)32-70 126 121 113 105 95 85 67 15 95 1040 500 1530 330 255 199
    CDL(F)32-80-2 136 131 123 114 102 90 71 15 102 1110 500 1600 330 255 203
    CDL(F)32-80 144 138 130 120 109 97 77 15 109 1110 500 1600 330 255 203
    CDL(F)32-90-2 154 148 140 129 117 102 82 18.5 117 1180 550 1720 330 255 222
    CDL(F)32-90 162 156 147 136 124 109 88 18.5 124 1180 550 1720 330 255 222
    CDL(F)32-100-2 175 166 157 146 131 115 91 18.5 131 1250 550 1790 330 255 227
    CDL(F)32-100 182 173 164 152 138 122 98 18.5 138 1250 550 1790 330 255 227
    CDL(F)32-110-2 193 184 173 164 146 128 102   22 146 1320 575 1885 360 285 272
    CDL(F)32-110 200 191 180 168 153 135 109   22 153 1320 575 1885 360 285 272
    CDL(F)32-120-2 211 201 189 178 160 140 113   22 160 1400 575 1955 360 285 276
    CDL(F)32-120 218 208 196 184 167 147 120   22 167 1400 575 1955 360 285 276
    CDL(F)32-130-2 230 218 206 193 174 153 124   30 174 1470 650 2100 360 285 293
    CDL(F)32-130 237 225 213 200 181 160 131   30 181 1470 650 2100 360 285 293
    CDL(F)32-140-2 247 235 222 210 189 165 135   30 189 1540 650 2170 360 285 298
    CDL(F)32-140 255 242 229 216 196 172 142   30 196 1540 650 2170 400 310 341
    CDL(F)32-150-2 266 253 239 224 213 178 145   30 213 1610 650 2240 400 310 345
    CDL(F)32-150 274 260 246 231 210 185 152   30 210 1610 650 2240 400 310 345
    CDL(F)32-160-2 284 270 255 240 218 190 156   30 218 1680 650 2330 400 310 350
    CDL(F)32-160 292 277 262 246 225 197 163   30 225 1680 650 2330 400 310 350

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Data Sheet

    Model 25 30 35 40 45 50 55 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
    Flow (45m³/h) B1 B2 H D1 D2
    CDL(F)42-10-1 20 19 18 17 15 13 11 Head (m) 3 15 561 345 906 197 165 83
    CDL(F)42-10 24 23 22 21 19 18 16 4 19 561 345 906 230 188 90
    CDL(F)42-20-2 40 38 36 33 30 27 23 5.5 30 641 390 1031 260 208 105
    CDL(F)42-20 48 46 44 42 39 35 31 7.5 39 641 390 1031 260 208 110
    CDL(F)42-30-2 63 61 58 54 50 44 38 11 50 826 500 1326 330 208 183
    CDL(F)42-30 71 69 66 63 58 53 47 11 58 826 500 1326 330 208 183
    CDL(F)42-40-2 87 84 80 75 69 62 54 15 69 906 500 1406 330 208 197
    CDL(F)42-40 95 92 88 84 78 71 62 15 78 906 500 1406 330 208 197
    CDL(F)42-50-2 111 107 102 96 88 80 69 18.5 88 986 550 1536 330 208 221
    CDL(F)42-50 119 115 110 105 97 88 78 18.5 97 986 550 1536 330 208 221
    CDL(F)42-60-2 135 130 124 117 108 97 85 22 108 1066 550 1616 360 285 261
    CDL(F)42-60 143 138 132 125 116 106 93 22 116 1066 550 1616 360 285 261
    CDL(F)42-70-2 158 152 146 138 127 115 100 30 127 1146 575 1721 400 310 320
    CDL(F)42-70 166 161 154 146 135 124 109 30 135 1146 575 1721 400 310 320
    CDL(F)42-80-2 182 175 168 159 146 133 116 30 146 1226 650 1876 400 310 324
    CDL(F)42-80 190 184 176 167 154 141 124 30 154 1226 650 1876 400 310 324
    CDL(F)42-90-2 205 198 190 180 166 150 132 30 166 1306 650 1956 400 310 328
    CDL(F)42-90 214 207 198 188 174 159 140 37 174 1306 650 1956 400 310 352
    CDL(F)42-100-2 230 221 212 200 185 168 147 37 185 1386 650 2036 400 310 355
    CDL(F)42-100 238 230 220 209 193 177 155 37 193 1386 650 2036 400 310 355
    CDL(F)42-110-2 255 246 236 223 206 188 165 45 206 1466 685 2151 460 340 426
    CDL(F)42-110 263 255 244 232 214 196 173 45 214 1466 685 2151 460 340 426
    CDL(F)42-120-2 280 270 259 245 226 206 181 45 226 1546 685 2231 460 340 432
    CDL(F)42-120 289 280 268 255 236 216 190 45 236 1546 685 2231 460 340 432
    CDL(F)42-130 305 294 282 267 247 225 198 45 247 1626 685 2311 460 340 438

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Data Sheet

    Model 30 40 50 60 65 70 80 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
    Flow (64m³/h) B1 B2 H D1 D2
    CDL(F)64-10-1 19 18 16 14 13 11 8 Head (m) 4 13 561 355 916 230 188 93
    CDL(F)64-10 27 25 23 21 20 18 15 5.5 20 561 390 951 260 208 105
    CDL(F)64-20-2 39 36 33 29 26 23 17 7.5 26 644 390 1034 260 208 110
    CDL(F)64-20-1 46 44 40 36 33 30 24 11 33 754 500 1254 330 255 182
    CDL(F)64-20 53 51 47 43 40 37 30 11 40 754 500 1254 330 255 182
    CDL(F)64-30-2 66 62 56 50 46 41 32 15 46 836 500 1336 330 255 196
    CDL(F)64-30-1 73 69 63 57 53 48 39 15 53 836 500 1336 330 255 197
    CDL(F)64-30 80 76 70 64 60 55 46 18.5 60 836 550 1386 330 255 221
    CDL(F)64-40-2 92 87 80 71 66 60 47 18.5 66 919 550 1469 330 255 225
    CDL(F)64-40-1 100 94 87 78 73 67 54 22 73 919 575 1494 360 285 258
    CDL(F)64-40 107 101 94 85 80 74 61 22 80 919 575 1494 360 285 258
    CDL(F)64-50-2 121 114 105 95 88 80 64 30 88 1001 650 1651 400 310 320
    CDL(F)64-50-1 128 121 112 102 95 87 71 30 95 1001 650 1651 400 310 320
    CDL(F)64-50 136 129 119 109 102 94 78 30 102 1001 650 1651 400 310 320
    CDL(F)64-60-2 150 142 131 118 110 101 81 30 110 1084 650 1734 400 310 325
    CDL(F)64-60-1 157 149 138 125 117 108 88 37 117 1084 650 1734 400 310 349
    CDL(F)64-60 164 156 145 132 124 115 95 37 124 1084 650 1734 400 310 349
    CDL(F)64-70-2 179 169 156 141 132 121 99 37 132 1166 650 1816 400 310 353
    CDL(F)64-70-1 186 176 163 148 139 128 106 37 139 1166 650 1816 400 310 353
    CDL(F)64-70 193 183 170 155 146 135 112 45 146 1166 685 1851 460 340 420
    CDL(F)64-80-2 207 196 182 164 154 142 116 45 154 1248 685 1933 460 340 424
    CDL(F)64-80-1 215 203 189 171 161 149 123 45 161 1248 685 1933 460 340 424

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Data Sheet

    Model 50 60 70 80 90 100 110 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
    Flow (90m³/h) B1 B2 H D1 D2
    CDL(F)85-10-1 22 19 17 16 13 10 6 Head (m) 5.5 13 571 390 961 260 208 105
    CDL(F)85-10 25 24 22 21 19 16 12 7.5 19 571 390 861 260 208 110
    CDL(F)85-20-2 41 39 36 32 28 22 15 11 28 773 500 1273 330 255 181
    CDL(F)85-20 53 50 47 44 40 36 30 15 40 773 500 1273 330 255 192
    CDL(F)85-30-2 68 65 60 55 49 41 32 18.5 49 865 550 1415 330 255 215
    CDL(F)85-30 81 77 72 67 62 55 48 22 62 865 575 1440 360 285 252
    CDL(F)85-40-2 98 93 87 80 72 62 50 30 72 957 650 1670 400 310 312
    CDL(F)85-40 110 105 100 92 84 76 66 30 84 957 650 1670 400 310 312
    CDL(F)85-50-2 126 120 113 104 93 81 68 37 93 1049 650 1699 400 310 336
    CDL(F)85-50 139 131 124 115 106 94 83 37 106 1049 650 1699 400 310 336
    CDL(F)85-60-2 155 148 139 129 117 102 86 45 117 1141 685 1826 460 340 407
    CDL(F)85-60 168 160 150 141 130 117 103 45 130 1141 685 1826 460 340 407

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Data Sheet

    Model 60 70 80 90 100 110 130 140 150 Flow (m³/h) Power (KW) Flow (120m³/h) Size(mm) Weight (KG)
    B1 B2 H D1 D2
    CDL(F)120-10 22 21 21.6 21 20 19 17 16 15 Head (m) 11 19 840 500 1340 330 255 230
    CDL(F)120-20-2 34 33 33 31 30 30 27 25 24 15 29 1000 500 1500 330 255 245
    CDL(F)120-20-1 41 40 39 38 37 36 32 30 27 18.5 35 1000 550 1550 330 255 250
    CDL(F)120-20 46 45 44 43 42 41 38 36 33 22 40 1000 575 1575 360 285 285
    CDL(F)120-30-2 57 56 55 53 52 51 46 43 41 30 49 1160 650 1810 400 310 360
    CDL(F)120-30-1 64 63 62 60 58 57 52 49 46 30 56 1160 650 1810 400 310 360
    CDL(F)120-30 69 68 67 66 64 62 57 54 51 30 61 1160 650 1810 400 310 360
    CDL(F)120-40-2 80 79 78 76 73 72 66 61 58 37 69 1320 650 1970 400 310 400
    CDL(F)120-40-1 87 86 84 82 80 78 72 68 64 37 76 1320 650 1970 400 310 400
    CDL(F)120-40 92.5 91 90 88 85 83 77 73 68 45 81 1320 685 2005 460 340 460
    CDL(F)120-50-2 104 103 101 99 96 93 85 80 75 45 90 1480 685 2165 460 340 470
    CDL(F)120-50-1 110 109 107 105 102 100 92 86 83 45 97 1480 685 2165 460 340 470
    CDL(F)120-50 115 114 113 110 107 104 96 91 86 55 102 1510 760 2270 540 370 575
    CDL(F)120-60-2 128 125 123 121 117 113 104 98 92 55 110 1670 760 2430 540 370 585
    CDL(F)120-60-1 134 132 130 127 124 121 111 105 100 55 118 1670 760 2430 540 370 585
    CDL(F)120-60 139 137 135 132 128 126 116 110 104 75 123 1670 845 2515 580 410 705
    CDL(F)120-70-2 151 148 145 143 138 134 123 116 109 75 130 1830 845 2675 580 410 715
    CDL(F)120-70-1 156 154 152 148 144 141 130 123 116 75 138 1830 845 2675 580 410 715
    CDL(F)120-70 162 160 158 155 151 148 137 129 123 75 145 1830 845 2675 580 410 715

    Performance Curves

    50HZ,2900rpm

    Installation Dimension Drawings

    Data Sheet

    Model 80 90 100 110 130 140 160 170 180 Flow (m³/h) Power (KW) Head (m) Size(mm) Weight (KG)
    Flow (150m³/h) B1 B2 H D1 D2
    CDL(F)150-10-1 18 18 17 17 15 14 11 10 8 Head (m) 11 13 840 500 1340 330 255 230
    CDL(F)150-10 24 23 22 22 20 20 17 16 15 15 18 840 500 1340 330 255 235
    CDL(F)150-20-2 37 35 34 33 31 29 26 23 21 18.5 28 1000 550 1550 330 255 250
    CDL(F)150-20-1 44 43 42 40 38 37 33 30 27 22 35 1000 575 1575 360 285 295
    CDL(F)150-20 50 49 48 47 44 42 37 34 32 30 40 1000 575 1575 400 310 360
    CDL(F)150-30-2 63 61 59 57 54 53 45 42 39 30 49 1160 650 1810 400 310 360
    CDL(F)150-30-1 70 68 67 65 62 60 53 49 45 37 56 1160 650 1810 400 310 360
    CDL(F)150-30 78 76 75 73 68 66 59 55 50 37 63 1160 650 1810 400 310 385
    CDL(F)150-40-2 89 87 84 81 77 74 65 60 56 45 71 1320 685 2005 460 340 460
    CDL(F)150-40-1 96 94 91 89 84 81 72 67 62 45 77 1320 685 2005 460 340 460
    CDL(F)150-40 104 102 100 97 91 88 79 74 68 55 84 1350 760 2110 540 370 560
    CDL(F)150-50-2 115 112 109 106 100 97 86 79 73 55 92 1510 760 2270 540 370 570
    CDL(F)150-50-1 122 119 117 113 107 104 93 87 80 75 99 1510 845 2355 580 410 690
    CDL(F)150-50 130 127 125 121 115 111 101 94 86 75 107 1510 845 2355 580 410 690
    CDL(F)150-60-2 140 137 133 130 121 118 106 98 91 75 112 1670 845 2515 580 410 700
    CDL(F)150-60-1 148 145 142 137 131 127 114 106 97 75 120 1670 845 2515 580 410 700
    CDL(F)150-60 157 153 149 145 139 137 123 116 109 75 130 1670 845 2515 580 410 700

     

About Us


Hebei Baixinda Industrial Water Pump Manufacturing Co., Ltd. is a professional manufacturer of new material equipment and wear-resistant spare parts integrating R&D, production, sales and service. It mainly serves industries such as mining, metallurgy, coal, power, environmental protection, chemical engineering and papermaking.
The company is committed to the research and application of high-performance ceramic wear-resistant and corrosion-resistant materials as well as ceramic composite materials to enhance the performance, reliability and service life of equipment, effectively save energy and reduce emissions, and improve the operation rate and operational efficiency of equipment. The new ceramic materials developed by the company have many advantages such as wear resistance, corrosion resistance, economy and environmental protection. They have partially replaced traditional metal materials, reduced the operation costs in industries such as mining, and achieved remarkable effects in energy conservation and environmental protection.

Assembly Workshop
Assembly
Filter press pump accessories
Mold
Casting
Finished goods warehouse
Finished product
150ZJ-I-C42 slurry pump tailings usage and installation site

Original manufacturer


Original manufacturer

Customer Inquiry

Factory quotation

Customer order

Factory production

Packaging and transportation

FAQ


Can you accept small quantities?

Yes, accept small quantity, fast delivery

Do you have pre-shipment inspection procedures?

Yes, we always test the products before delivery.

Can I take samples for testing?

Yes, samples can be sent for testing before bulk ordering.

When is the delivery time?

Inventory orders within 7-15 days, for oem and odm orders, the specific time depends on the actual situation.

What are the terms of payment?

Wire transfer or letter of credit, Western Union, Alipay, etc.

What is the minimum order quantity?

It depends on the product.

Product inquiry